Input Voltage: | |
---|---|
Battery: | |
Emergency duration: | |
Charging time: | |
Power Consumption: | |
Availability: | |
Quantity: | |
Relavent Standard
EN 60598-1 | EN 61000-3-2 | IEC 60598-1 | IEC61000-3-2 |
EN 60598-2-22 | EN 61000-3-3 | IEC 60598-2-22 | IEC 61000-3-3 |
EN 61347-1 | EN 62471 | IEC 61347-1 | IEC 62471 |
EN 61347-2-13 | EN 62493 | IEC 61347-2-13 | IEC 62493 |
EN 61347-2-7 | EN 55015 | IEC 61347-2-7 | IEC 55015 |
EN 62778 | EN62031 | IEC 62778 | IEC62031 |
Product Parameter
Model No.: | LEK02-3L | Battery: | Li-ion, 3.7V 1800mAh |
LED Chips: | CREE XT-E | Luminous Flux: | 150lm |
Power Consumption: | 3W | Input Voltage: | AC220-240V~50/60Hz |
Charge time: | 24Hours | Emergency duration: | 3Hours |
ta: | 0~35℃ | Max. Case Temp.: | 70℃ |
Protection Class: | II | IP Rating: | IP20 |
Operation: | Non-maintained | Function: | AUTO test |
Dimension
Special Notes
● This product should be installed by a registered electrician in accordance with local standards and electrical regulations;
● Take care to ensure the mains supply is isolated before installation;
● The light source of this luminaire is not replaceable; when the light source reaches its end of life, the whole luminaire shall be replaced;
● The whole luminaire should be replaced when they no longer meet their rated duration of operation after the corresponding recharge period.
Relavent Standard
EN 60598-1 | EN 61000-3-2 | IEC 60598-1 | IEC61000-3-2 |
EN 60598-2-22 | EN 61000-3-3 | IEC 60598-2-22 | IEC 61000-3-3 |
EN 61347-1 | EN 62471 | IEC 61347-1 | IEC 62471 |
EN 61347-2-13 | EN 62493 | IEC 61347-2-13 | IEC 62493 |
EN 61347-2-7 | EN 55015 | IEC 61347-2-7 | IEC 55015 |
EN 62778 | EN62031 | IEC 62778 | IEC62031 |
Product Parameter
Model No.: | LEK02-3L | Battery: | Li-ion, 3.7V 1800mAh |
LED Chips: | CREE XT-E | Luminous Flux: | 150lm |
Power Consumption: | 3W | Input Voltage: | AC220-240V~50/60Hz |
Charge time: | 24Hours | Emergency duration: | 3Hours |
ta: | 0~35℃ | Max. Case Temp.: | 70℃ |
Protection Class: | II | IP Rating: | IP20 |
Operation: | Non-maintained | Function: | AUTO test |
Dimension
Special Notes
● This product should be installed by a registered electrician in accordance with local standards and electrical regulations;
● Take care to ensure the mains supply is isolated before installation;
● The light source of this luminaire is not replaceable; when the light source reaches its end of life, the whole luminaire shall be replaced;
● The whole luminaire should be replaced when they no longer meet their rated duration of operation after the corresponding recharge period.